Galway Drum Pump Specifications
  • Suction Tubes are 1.5 inch OD Schedule 80 pipe, Mixer tube and pump are interchangeable. Standard tube length is 39.5 inch (100cm) Custom lengths from 2 to 8 ft available.
  • Pumps are a Halar ECTFE two-stage impeller,
  • Shaft bushings are low friction non-moving carbon-graphite/PTFE
  • Pump shafts are Hastelloy-C
  • In-stock pump materials are CPVC, PVDF and Poly. (Halar, FEP or other materials are available upon order)
400 Series Pump Curves:
YC4-100

Model Y Motor

The 1/2 HP at 8000 RPM motor provides a maximum pumping rate of approximately 20 gallons per minute. Shutoff head is about 17 feet (water sg 1.0). The Model Y motor will handle specific gravities up to 1.6 and viscosities over 100 SSU. YC4-100 PUMP CURVE

Model Y Motor w/ C4-100 Pump

WC4-100

Model W Motor

This 1.1 HP motor at 16,000 RPM provides a maximum pumping rate in excess of 50 gallons per minute. Shutoff head is approximately 40 feet (water sg 1.0) . The Model W motor will handle specific gravities up to 2.0 and viscosities over 1100 SSU. W/C4-100 PUMP CURVE

Model W Motor w/ C4-100 Pump

SC4-100

Model S Motor

The 1/2 HP at 6000 RPM performance provides a maximum pumping rate of about 20 gallons per minute. Shutoff head is approximately 17 feet (water sg 1.0). SC4-100 PUMP CURVE

Model S Motor w/ C4-100 Pump

Material CPVC Polypropylene PVDF
Model No. C4-100 Cm-100 P4-100 Pm-100 K4-100 Km-100
Type Pump Mixer Pump Mixer Pump Mixer
Custom pumps may be manufactured to your specifications. Contact us all for availability of materials not listed. All of the above 400 Series Pumps are interchangeable with any Galway Drive Unit.


Galway Pumps


Home Pumps Drives Specs Parts Pricing


The specifications contained herin are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are current. The manufacturer assumes no responsibility for any use of these specifications. Any warranties exclude normal usage, abuse and misuse. © Galway Pumps 1996